Please Note
The Insertion and Removal of HI/Mate-D
lead Assemblies into a Positronic Sub-D connector is presented in 4 steps.
Please follow the instructions in this document when inserting or removing
a Hi/Mate lead assembly into or from a Sub-D connector.
View
this process NOW |
Design
Verification Testing
In house verification testing has been conducted on HI/Mate-D
lead assemblies. The chart below describes the tests and the results.
Note: Tests performed using Positronic CBD connectors.
| Test
Description |
Results |
Dielectric Withstanding
Voltage: 18 KVDC
@ 70,000 feet, ambient temperature |
Passed. Leakage
current: <10 µA |
Altitude/Thermal
Shock: 70,000 feet;
-65°C To +125°C; 25 Cycles Operating
at 15 KVDC |
Passed. Leakage
current: <10 µA |
| Contact Retention:
22 Pounds |
Passed. See